ISE from Ansell Electronics

ISE

directION electrodes

Do you measure Ammonium, Chloride, Fluoride, Calcium or Nitrate in water?

Have you used conventional Ion selective electrodes?

If the answer to any of these questions is yes, then directION electrodes are just what you've been looking for!

 

 

Main features and benefits include:

  • No reference electrode needed
  • No filling solution
  • Fully submersible and waterproof
  • Virtually unbreakable
  • Solid state sensors
  • Colour coded caps for identification in the field
  • Can be left dry for long periods
  • Ideal for unskilled operatives
  • Long lifetime

Product Description

directION electrodes are rugged solid state sensors with built in reference elements that do not require any filling solution or maintenance.

Fully Submersible

directION electrodes are waterproof and submersible. This gives the field operative the ability to cast the probe into the water from awkward sample points, bridges, banks and boats.

Cable length can be stipulated at the time of ordering. Maximum length is 10 metres. Standard products are fitted with 1 metre of cable terminated with a BNC connector.

Laboratory or field use

Though directION electrodes have a rugged and waterproof construction, there has been no compromise on technical specification (see table below). Standard Ion selective performance is surpassed under both laboratory and field conditions.

What meter can I use?

directION electrodes can be used with any conventional laboratory or hand held pH meter with a millivolt display mode. Please stipulate the connector required on your order.

ORDER
NUMBER
directION
ELECTRODE
CONCENTRATION
RANGE
(Mol/L)
LIMITS
(ppm)
pH
RANGE
TEMP
RANGE
(°C)
MAIN
INTERFERENCES
ISAB
362-75 Ammonium
(NH4+)
5 x 10-1 - 5 x 10-5 9000 -
0.09
1 - 8.6 0 - 50 K+, Na+ CH3COOH
368-75 Barium
(Ba2+)
10-1 - 10-5 1.4 -
13,700
3 - 10 0 - 50 Sr2+, K+, Na+ CuSO4
375-75 Bromide
(Br-)
100 - 5 x 10-5 0.4 -
80,000
1 - 12 0 - 50 I-, CN-, S2- 5M KNO3
373-75 Cadmium
(Cd2+)
10-1 - 1 x 10-5 0.1 -
11,200
3 - 7 0 - 50 Hg2+, Ag+, Cu2+ Pb2+, Fe3+ 5M KNO3
361-75 Calcium
(Ca2+)
10-1 - 5 x 10-7 4,010 -
0.02
3.5 - 11 0 - 50 Ba2+, Al3+, Sr2+ KCI
369-75 Carbonate
(CO32-)
10-3 - 10-7 0.008 -
80
6.6 - 9.6 0 - 50 SCN-, I-, NO3- NO2-, CH3COO- NaHCO2
364-75 Chloride
(Cl-)
100 - 3 x 10-6 35,500 -
1
1 - 12 0 - 50 I-, Br-, CN-, S2- 5M KNO3
379-75 Cupric
(Cu2+)
100 - 1 x 10-7 0.008 -
84,000
2 - 7 0 - 50 Hg2+, Ag+, S2- Cl-, Br- 5M KNO3
377-75 Cyanide
(Cn-)
10-2 - 1 x 10-5 0.03 -
260
11 - 13 0 - 50 I-, S2- 10M NaOH
365-75 Fluoride
(F)
10-1 - 1 x 10-8 1,900 -
0.02
4 - 8 0 - 50 OH- TISAB
376-75 Iodide
(I-)
100 - 5 x 10-7 0.06 -
127,000
2 - 12 0 - 50 CN-, S2- 5M KNO3
372-75 Lead
(Pb2+)
10-1 - 1 x 10-5 0.2 -
20,800
3 - 7 0 - 50 S2-, Hg2+, Ag+ Cu2+, Fe3+, Cd2+ 5M NaCIO4
374-75 Mercury
(Hg2+)
100 - 1 x 10-6 0.2 -
201,000
0 - 2 0 - 50 Ag+, S2- 5M NaCIO4
360-75 Nitrate (NO3-) 100 - 7 x 10-6 62,000 -
0.4
2 - 11 0 - 50 CI-, NO2 4M (NH4)2SO4
367-75 Perchlorate
(CIO4-)
100 - 2 x 10-1 0.2 -
99,500
0 - 11 0 - 50 I-, SCN-, NO3- CH3COONa
366-75 Potassium
(K+)
100 - 10-5 0.04 -
39,000
1 - 9 0 - 50 Cs+, NH4+ 4M KCl
371-75 Silver
(Ag+)
100 - 1 x 10-7 0.01 -
107,900
1 - 9 0 - 50 S2-, Hg2+ 5M KNO3
315-75 Sodium
(Na+)
Sat - 10-6 1 ppb 9 - 12 0 - 50 Ag+, NH4+, Li+, K+ SISAB
378-75 Sulphide
(S2-)
100 - 1 x 10-7 0.003 -
32,000
13 - 14 0 - 50 Ag+, Hg2+ 10M NaOH
380-75 Thiocyanate
(SCN-)
10-1 - 2 x 10-6 1 -
5,800
2 - 12 0 - 50 I-, Cl-, S2- 5M KNO3
370-75 Water
Hardness
2 x 10-1 - 5 x 10-5 - 4.5 - 10 0 - 50 Ba2+, Sr2+, Cd2+ Cu2+, Na+, K+, NH4+ LiAC

NOTE:

The directION electrodes shown above are rugged solid state sensors with built-in reference electrodes that do not require any filling solution or maintenance